Fluke 9142 field metrology well
WebFluke Calibration 9142 Field Metrology Well. The 9142 Series Field Metrology Wells extend high performance to the industrial process environment... Fluke Calibration 9143 Field Metrology Well. ... The … WebThe Fluke 9142 Field Metrology Well extends high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to …
Fluke 9142 field metrology well
Did you know?
WebOur field metrology wells provide the best combination of speed, stability, and accuracy in a field calibration temperature source. They are suitable for calibrating thermocouples, … WebCombined, the three models (Fluke 9142, Fluke 9143, and Fluke 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C. High performance for the industrial environment Field Metrology …
WebModels: 9142-4 Field Metrology Wells Carrying Case. 9142-CASE. Field Metrology Wells Carrying Case. bvseo_sdk, p_sdk, 3.2.1; CLOUD, getContent, 46.21ms; ... Fluke Calibration 9142 Field Metrology Well; … WebCombined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C. High performance for the industrial environment. Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small ...
WebFor Metrology Wells, we define our specification as the largest temperature difference between the vertically homogeneous zones of any two wells that are each 6.4 mm (0.25 in) in diameter or smaller. The cold units (9170 and 9171) provide radial uniformity of ±0.01 °C and the hot units (9172 and 9173) range from ±0.01 °C to ±0.04 °C (at 700 °C). WebFluke 9142-DW-156 Field Metrology Well (No Insert), -25 to 150°C Model:9142-DW-156 Be the first to review this product Use this field metrology well to perform transmitter loop calibrations, comparison calibrations or simple thermocouple sensor checks. With plenty of remarkly easy functions, this field metrology well comes without an insert.
WebThe 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance. Field Metrology Wells are packed with functionality and are remarkably easy to use.
WebFluke 9142-A-P-156 Low Temp Process Field Metrology Well Offers Features Each process version provides built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA … designer drafter north side chicagoWebThe 9142 and 9143 have a display accuracy of ±0.2 °C over their full range, and the 9144 display accuracy ranges from ±0.35 °C at 420 °C to ±0.5 °C at ±660 °C. Each calibration is backed with a 4:1 test uncertainty ratio. New control technology guarantees excellent performance in extreme environmental conditions. chubbys cheesesteaks menuWebFluke Calibration 9142-DW-P-156 Dry-Well Field Calibrator, 115V No Insert, with Built-in Elct. $9,993.00 Add to Cart Fluke Calibration 9143-C-156 Mid-Temperature Dry-Well Field Calibrator with 9143-INSC, 115V $6,614.00 Add to Cart Fluke Calibration 9142-E-P-156 Dry-Well Field Calibrator, 115V with 9142-INSE & Built-in Elct $10,536.00 Add to Cart chubby scooter wheelsWebFluke 9142 – Field Metrology Wells $ 10,362.00 $ 9,999.00 Excluding GST 10% Key Features: Lightweight, portable, and fast Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ±0.01 °C On-board automation and documentation designer doors and windows burbank caWebThe 9142 and 9143 have a display accuracy of ±0.2 °C over their full range, and the 9144 display accuracy ranges from ±0.35 °C at 420 °C to ±0.5 °C at ±660 °C. Each calibration is backed with a 4:1 test uncertainty ratio. New control technology guarantees excellent performance in extreme environmental conditions. designer draftsman in utah countyWebDec 16, 2016 · The 9142 is stable to ±0.01 °C over its full range and the mid-range 9143 is stable from ±0.02 °C at 33 °C and ±0.03 °C at 350 °C. … chubby scuba womanWebFluke Calibration Calibrator, Field Metrology Well, Insert A, -25 to 150 C, Process Electronics Fluke 9142-A-P-156 RoHS: Not Compliant Min Qty: 1 Package Multiple: 1 Container: Bulk: 0 1 $10,536.0000 RFQ TAP156M025BRW DISTI # 73977204. Kyocera AVX Components ... designer drains without screw holes